Coefficient of performance

COP

The coefficient of performance (COP) is the heat a heat pump delivers divided by the electricity it uses, measured at one set of conditions; electric resistance heat has a COP of 1.

COP compares heat out with energy in, both in the same units. A COP of 3 means three units of heat for each unit of electricity. A heat pump can exceed 1 because it moves heat from the outdoor air rather than making it. A resistance heater turns each unit of electricity into one unit of heat, a COP of 1.

A COP describes one operating point: one outdoor temperature, one indoor temperature, one compressor speed. It falls as the outdoor air gets colder, which is why cold-climate ratings quote it at 5 °F (−15 °C). ENERGY STAR’s Cold Climate designation requires at least 1.75 there. Units built for the DOE Cold Climate Heat Pump Challenge had to reach 2.4 or 2.1 at 5 °F, depending on their size.

A single COP is not a seasonal figure. For a whole heating season, the federal rating is HSPF2.

Sources

  1. ENERGY STAR — Central Air Conditioner and Heat Pump Specification, Version 6.2 (Rev. March 2025)
  2. U.S. DOE — Residential Cold-Climate Heat Pump Technology Challenge specification (October 2021)